Examining the Effects of Fluid Velocity Gradients on 4D Digital Holographic PIV/PTV Measurements

Authors

  • Yuan Jing Xia Monash University, Australia
  • Bihai Sun Monash University, Australia
  • Asif Ahmed Monash University, Australia
  • Julio Soria Monash University, Australia

DOI:

https://doi.org/10.18409/ispiv.v1i1.112

Keywords:

Digital Holography, PIV, 4D, velocity gradient, error

Abstract

4D digital holographic PIV/PTV (4D-DHPIV/PTV) methods have demonstrated theoretical viability due to their relative ease of setup and high spatial resolution (Soria (2018)). This study investigates how velocity gradients related to different flow regimes and their magnitudes affect 3-component–3-dimensional (3C-3D) digital holographic PIV measurement uncertainty.

The error introduced by velocity gradients within the interrogation volume is studied by simulating particles in a velocity field, with a given constant velocity gradient superimposed on a uniform flow from which a time-series of hologram pairs are generated and the 3C-3D velocity fields and their errors are determined using 4D-DHPIV/PTV Sun et al. (2020). Hologram pairs are simulated by modelling the propagation and particlediffraction of coherent laser light using the angular spectrum method (Goodman (1996)). The hologram reconstruction then involves direct reconstruction, followed by deconvolution, a particle position refinement and a hologram subtraction step (Sun et al. (2020)). The particle positions obtained from 4D-DHPIV/PTV are then used to resolve particle displacement measurements using 3D cross-correlation digital analysis with a 3D Gaussian fit to sub-pixel resolution (Soria (2006)).


The effects of velocity gradients on the displacement uncertainty and bias error have been investigated by undertaking Monte Carlo simulations under a range of velocity gradient environments. Specifically, 5 common velocity gradients have been studied, which included pure strain, pure vorticity and x, y and z-directional shear.

The results indicate that the novel 4D-DHPIV/PTV has poorer accuracy and precision in the z-propagation axis, resulting in larger minimum uncertainties and bias errors. The errors in the z axis are also significantly less affected by velocity gradients in the z direction when compared to the effects of x and y directional velocity gradients on x and y errors respectively. Furthermore, the rate of cross-correlation maximum and SNR decrease are approximately 1.36 times slower due to velocity gradients in the z axis than other axes.

 

Downloads

Published

2021-08-01

Issue

Section

3D Methods and Applications